A lung dosimeter that can record the nonradiological hazard of aerosol particles to the lung as well as the radiological hazard of air borne radionuclides that are attached to aerosol particles has been developed. The dosimeter is capable of recording aerosol particles of diameters from 10–2 μm to 102μm by electro-static collection in a specially designed dosimeter body. The aerosol size distribution is recorded on a mylar strip and the activity size distribution of α, β, and γ radiation emitting aerosols are recorded on another strip coa...