Wastewater containing uranium was treated by ZVI - SRB under hypoxic conditions. The initial uranium concentration, SO42-, NO3 - and pH on ZVI- SRB uranium precipitation are studied through orthogonal experiment. The result shows that the initial uranium concentration influencesmost greatly on the removal rate, following SO42- , NO3 - and pH. The optimal removal conditions for 500 mL wastewater containing uranium are the initial uranium concentration 160 mg/L, pH5, SO42- 3 000 mg/L, NO3 - 400 mg/L. The removal effic...