Objective To explore the dosimetric effects of ovaries sparing in linear accelerator(LA)radiotherapy for cervical cancer on planning target volume(PTV)and organs-at-risk(OAR).Methods Sixteen patients treated with ovaries-sparing LA radiotherapy for cervical cancer were randomly selected,and 7-field IMRT plans were designed for each patient based on XiO treatment planning system.The 95% of PTV receiving 45 Gy irradiation dose was achieved by normalization.With the same optimization parameters except the treatment of ovaries,two groups of treatme...