Pull-push ventilation system, with high capture efficiency, is universally used to capture contaminants from containment generation where can't be enclosed and where the working area is large. When there are obstacles between the pull hood and the push hood, the air jet will disperse, leaving contaminants out of control, causing atmosphere polluted. This paper aims to discuss flow filed of pull-push ventilation system, located in some tank of some plating workshop, with obstacles between pull hood and push hood. Mathematical model, involving physical model, assumptions, governing equations, bo...