In order to maintain small statistical error, isotic mould level gauge always performs measurement with longer measuring time. Howover, dynamic measurement error will be higher due to longer measuring time when mould level changes rapidly. Hence, fuzzy logic was employed to control the mould level gauge operation and adjust the measuring time according to variation of mould level. Simulation results show that the proposed method improves both the dynamic...