Optimized inverse distance weighted interpolation algorithm for γ radiation field reconstruction

认领
导出
Link by DOI
反馈
分享
QQ微信 微博
成果类型:
期刊论文
作者:
Zhang, Biao;Cao, Jinjia;Lin, Shuang;Li, Xiaomeng;Zhang, Yulong;...
通讯作者:
Cao, JJ
作者机构:
[Zhang, Biao; Zhang, Yulong; Chen, Wei; Li, Xiaomeng; Zheng, Xiaochang; Cao, Jinjia; Song, Yingming] Univ South China, Sch Nucl Sci & Technol, Hengyang 421001, Peoples R China.
[Lin, Shuang] China Nucl Power Engn Co Ltd, Instrument Control Design Inst Beijing, Nucl Engn Res & Design Inst, Beijing 100142, Peoples R China.
通讯机构:
[Cao, JJ ] U
Univ South China, Sch Nucl Sci & Technol, Hengyang 421001, Peoples R China.
语种:
英文
关键词:
Radiation fields of multiple gamma source;Optimized IDW;MAPE;Geant4;Decommissioning of nuclear facilities
期刊:
Nuclear Engineering and Technology
ISSN:
1738-5733
年:
2024
卷:
56
期:
1
页码:
160-166
基金类别:
Research on real-time Perception and Model Reconstruction of Nuclear Facility Radiation Field of China National Nuclear Corporation "Young Talents" Project [KY20029]; ITER Project of Ministry of Science and Technology [2022YFE03080002]; Key Fund Project of Hunan Provincial Department of Education [20A417]; PhD Foundation of the University of South China [2017XQD08]
机构署名:
本校为第一且通讯机构
院系归属:
核科学技术学院
摘要:
The inversion of radiation field distribution is of great significance in the decommissioning sites of nuclear facilities. However, the radiation fields often contain multiple mixtures of radionuclides, making the inversion extremely difficult and posing a huge challenge. Many radiation field reconstruction methods, such as Kriging algorithm and neural network, can not solve this problem perfectly. To address this issue, this paper proposes an optimized inverse distance weighted (IDW) interpolation algorithm for reconstructing the gamma radiation field. The algorithm corrects the difference be...